Cat.7 network installation cable, PiMF, 100 ohms, 10 GB, AWG 23, 1000 MHz, FRNC-B, orange, length 500 m
Cat.7 network installation cable, PiMF, 100 ohms, 10 GB, AWG 23, 1000 MHz, FRNC-B, orange, length 500 m
Cat.7 network installation cable, S/FTP PiMF, 1000 MHz, AWG 23/1, 500 m, orange
500 m Cat.7 cable on a reel for fixed, shielded network cabling up to 1000 MHz and up to 10 Gbit/s, depending on the components used.
Quick overview
Category:
Cat.7 installation/laying cable
Shielding:
S/FTP with PiMF
Conductors:
4 × 2 × AWG 23/1, solid
Frequency:
up to 1000 MHz
Length:
500 m on a reel
Sheath / Colour:
FRNC-B, orange
Advantages
- S/FTP construction with pair-by-pair foil screening (PiMF) and additional overall braided screen
- Designed for transmission frequencies up to 1000 MHz
- Data transmission up to 10 Gbit/s depending on total distance and connection components
- Solid AWG-23/1 conductors for permanent installation
- 500-metre reel for large-scale network and building installations
- FRNC-B sheath in orange, halogen-free
Product description
The Cat.7 network installation cable C7-500S is a shielded installation cable for structured LAN and Ethernet cabling. The 500-metre reel is intended for permanent installations and features four individually screened wire pairs in an S/FTP PiMF configuration.
The construction consists of 4 × 2 solid AWG-23/1 conductors. The pair-by-pair foil shielding is supplemented by an overall braid, thereby supporting low-interference signal transmission in installation environments with heightened EMC requirements.
The cable is designed for frequencies up to 1000 MHz and a characteristic impedance of 100 ohms. In appropriately configured network links, data rates of up to 10 Gbit/s are possible. The actual performance achievable depends on the total length of the cabling run, the connection components and professional installation.
Areas of application
- Structured building cabling in office and administrative buildings
- Data centres and server rooms
- Backbone and horizontal cabling
- Industrial IT and automation environments with heightened EMC requirements
- Network distribution and system integration projects
- Network runs in the vicinity of control cabinets with suitable connection components
Technical data
Product type
Network installation cable / laying cable, supplied on reels
Category
Cat.7
Shielding
S/FTP, PiMF
Conductors / Construction
4 × 2 × AWG 23/1, solid
Conductor
Copper wire, bare, Ø approx. 0.56 mm
Conductor insulation
Foam-skin polyethylene, Ø approx. 1.35 mm
Pair shielding
Aluminium-coated plastic composite foil
Overall shielding
Tinned copper braiding, approx. 35% coverage
Characteristic impedance
100 ohms
Frequency range
up to 1000 MHz
Data rate
up to 10 Gbit/s, depending on total length and components
Sheath
FRNC-B, halogen-free
Outer diameter
approx. 7.3 mm
Colour
Orange
Length
500 m
Item number
C7-500S
EAN
4032528026329
Weight
approx. 25.86 kg per roll
Standards
ISO/IEC 11801 (AMD 2:2009), EN 50173-1 (2009)
Channel classes
E / EA / F / FA for a suitably designed overall route
Compatibility
Suitable for structured cabling systems with compatible Cat.6A/Cat.7 connection components, such as keystone modules, patch panels and network sockets. Separate patch cables are usually used to connect active devices such as switches, routers or PCs. The achievable transmission class is determined jointly by the cable, connection components and installation.
Installation notes
The cable is designed with solid conductors for fixed installation and is not intended for use as a flexible device patch cable.
The specified minimum bend radius during installation is at least 8 times the cable diameter, and at least 4 times the cable diameter once installation is complete.
Selection and practical guidelines
For a Cat.7 cabling run, the network sockets, Keystone modules and patch panels used should be selected to match the required category or channel class.
The 500-metre roll is particularly suitable for larger installation projects involving multiple cable routes, rooms or network connections.
FAQ
Is the Cat.7 cable intended for fixed installation?
Yes. The solid AWG 23/1 conductors are designed for fixed network and building installations.
What type of shielding does the installation cable have?
The cable is of the S/FTP type. The wire pairs are individually shielded with foil (PiMF); there is also an overall braided shield.
What transmission performance does the cable support?
The cable is designed for frequencies up to 1000 MHz and data rates up to 10 Gbit/s. The actual performance achievable depends on the total length of the run and the connection components used.
Which connection components can be used?
Suitable components include appropriately rated network sockets, Keystone modules and patch panels for structured Cat.6A/Cat.7 cabling.
How long is the cable reel?
The C7-500S is available as a 500-metre roll in orange.
Item C7-500S